Sherwood 9000 Series & Genesis Prana 1st Stages
Service Procedures on Sherwood 9000 Series & Genesis Prana 1st Stages
The Sherwood Scuba 9000 Series and the Genesis Prana 1st Stages are amazing environmentally sealed, balanced, flow-by piston regulators that build upon the Sherwood & Genesis principles of rugged reliability combined with ease of maintenance.
Statement of Understanding
FREE PREVIEWSection 1 - Introduction
Introduction Presentation
Quick note explaining Quizzes and Final Exam.
Certificates
Reference Material Use
Sherwood_9000SeriesFirstStag ServiceManual.v2020
9000 Series 1st Stage Shematics
9000_1StStageKitcomponentsSingleCard
Use of videos
Basic Regulator Knowledge Quiz
Disassembly Procedures
Disassembly Presentation
Disassembly Procedures - Quiz
Disassembly Videos
CapRemoval
Yoke Retainer Removal
Yoke Base O-ring Removal
Retaining Ring & Filter Removal
Yoke Retainer O-rings Removal
Diaphragm Removal
Orifice Removal
Backup Ring Removal
Schrader Valve Removal
Cleaning and Inspection Presentation
Lubrication Presentation
Reassembly Part 1
Reasembly Part 1.pdf
Reassembly Part 1 - Quiz
Reassembly Part 2
Reassembly Part 2 Presentation
Reassembly Part 2 - Quiz
Reassembly Videos
Orifice Installation
Schrader Valve Installation
Orifice Retainer Torque
Diaphragm Installation
StemO-Ring Install
Piston Installation
End Cap Installation
Yoke Retainer Installation
Final Testing Procedures - Required Reading
Final Testing and Calibration Presentation
Final thoughts before moving to the Final Exam
Final Exam
Mauricio Moreno